Permit: T03CM04198

Parcel: 119032880


Addresses:

740 W 42ND ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/28/2004 FRAMING Approved IVRS - Inspection :*
10/21/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
10/04/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) FIRE BLOCK DROP CEILINGS 2) SHIM ENTRY HEADER HANGER TO CARRY LOAD 3) ANCHOR BOLTS REQUIRED WITHIN 12" OF PLATE SPLICES 4) PEX PLUMBING NOT ALLOWED WITHIN 12" OF RECESSED LIGHTS (KITCHEN) 5) BLOCK DEFUSER BOOTS 3 SIDES 6) PROVIDE ATTIC ACCESS TO 22 X 30 FURNACE WITH CATWALK 7) PROVIDE A/C CONDENSATES 8) LAUNDRY DOOR TO SMALL 9) INSTALL WATER HEATER VENT AND T & P LINE 10) LATH PARTIAL. HOUSE OK, NOT PORCH 11) PROVIDE 3-4 X 6 HEADER AT W/H