Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/28/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/21/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 10/04/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) FIRE BLOCK DROP CEILINGS 2) SHIM ENTRY HEADER HANGER TO CARRY LOAD 3) ANCHOR BOLTS REQUIRED WITHIN 12" OF PLATE SPLICES 4) PEX PLUMBING NOT ALLOWED WITHIN 12" OF RECESSED LIGHTS (KITCHEN) 5) BLOCK DEFUSER BOOTS 3 SIDES 6) PROVIDE ATTIC ACCESS TO 22 X 30 FURNACE WITH CATWALK 7) PROVIDE A/C CONDENSATES 8) LAUNDRY DOOR TO SMALL 9) INSTALL WATER HEATER VENT AND T & P LINE 10) LATH PARTIAL. HOUSE OK, NOT PORCH 11) PROVIDE 3-4 X 6 HEADER AT W/H |