Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM04198

Parcel: 119032880


Addresses:

740 W 42ND ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
07/13/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/12/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) CLIP ENDS OF GABLE END TRUSSES 2) DOUBLE TOP PLATE SPLICE LESS THAN 48" AT GARAGE FRONT PORCH HEADER-INSTALL FHA STRAP ON BOTTOM PLATE 3) PORCH LEDGER NOT CLIPPED PER X/S-2 4) PORCH POST CAPS NOT INSTALLED 5) CLIP KING STUDS 6) A-1 TRUSSES MISSING TRUSS BRACES 7) DOUBLE KING STUDS REQUIRED AT GARAGE JAMBS