Permit: T03CM04175

Parcel: 115043950


Addresses:

1125 N 1ST AV


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T03CM04175

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
10/14/2003 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
10/08/2003 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*/ 1) SAME RESULTS AS PREVIOUS INSPECTION
09/12/2003 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*/ 1) WET VENTING PERMITTED ONLY IN VERTICAL VENT SITUATION 2) 10' WATER TEST REQUIRED ON ALL DWV LINES. 3) FLAT VENTING ONLY PERMITTED WHERE REQUIRED BY STRUCTURAL CONDITIONS