Permit: T03CM04174

Parcel: 113050290


Addresses:

2237 E GREENLEE RD

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/22/2004 FRAMING Approved IVRS - Inspection :*
06/18/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) INSTALL WEEP SCREED AND FINISH NAILING OFF LATH 2) STILL MORE A.B.'S REQUIRED AT BOTTOM PLATES
06/16/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) ANCHOR BOLTS REQUIRED WITHIN ONE FOOT OF END OF BOTTOM PLATE 2) A SUB ELECTRIC PANEL REQUIREST SEPERATE GROUND AND NEUTRAL BARS 3) UNUSED HOLES IN BOXES MUST BE PLUGGED
05/25/2004 FRAMING Not ready for Inspection IVRS - Inspection :*/ 1) FRAMING INSPECTION WILL BE DONE AFTER ELECTRIC IS IN 2) OK TO DRY-IN ROOF AND WALLS