Permit: T03CM04151

Parcel: 126050460


Addresses:

4122 E SPEEDWAY BL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/26/2004 PLUMBING - FINAL Approved IVRS - Inspection :*/ BACKFLOW DEVICE UNDER BAR SINK HAS BEEN REMOVED. TESTING OF OTHER BACKFLOW DEVICE OK.
04/21/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) PLEASE PROVIDE TESTING ON BACKFLOW DEVICES AS PER LAST REQUEST. 2) CODE VIOLATION ON BACKFLOW DEVICE AT BAR SINK. PLEASE PROVIDE AN APPROVED RECEPTOR FOR INDIRECT WASTE FOR BACKFLOW DEVICE AT BAS SINK NOT ON PLAN AT THIS TIME. PLEASE HAVE YOUR PLBR SEE DEFINITIONS 94 UPC ON RECEPTOR.
04/12/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ PLEASE PROVIDE TESTING ON ALL BACKFLOW DEVICES. ALSO COFFEE MAKER REQUIRES ITS OWN BACKFLOW DEVICE. - BAR SINK BACKFLOW DEVICE INDIRECT WASTE NOT TO CODE - NEED TO RUN INDIRECT WASTE FROM BACKFLOW DEVICE TO AN APPROVED LOCATION.
04/08/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) PROVIDE CORRECT DRAINAGE AND FITTINGS FOR BAR SINK. 2) PROVIDE FULL SIZE H2O TO BACKFLOW DEVICE UNDER BAR SINK. 3) PROVIDE BACKFLOW CERTIFICATION. 4) WTR HTR T&P TO GRAVITY DRAIN TO DAYLIGHT OR TO APPROVED RECEPTOR. 5) WTR HTR EXPANSION TANK TO BE SECURED. 6) ALL INDIRECT DRAINS TO HAVE 1" AIR GAP.
02/06/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ OK FOR TEMP C OF O SUBJECT TO OTHER INSP. CAP OFF FLOOR SINK. INSTALL ICE MAKER AND BACKFLOW DEVICE. BACK ORDER ON BAR SINK.
01/26/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ GREASE TRAP UNDER SIZED SEE PLAN APPROV. 20 # GREASE TRAP. NOTE SEE PLAN ALL FIXTURES GO THRU GREASE TRAP.