Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/18/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 11/17/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) HOUSE BEING INSULATED BEFORE APPROVAL. REMOVE ALL INSULATION FOR INSPECTION |
| 11/14/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) STUD MISSING NORTH WEST CORNER 2) MISSING RED HEADS INTERIOR TRANSFER WALL 3) NAIL PROTECT ELECTRIC AT GARAGE WITHIN 1 1/4" FROM EDGE 4) COMPLETE ELECTRICAL AT LAUNDRY 5) NO TEST ON DWV'S 6) PEX NEEDS 12" CLEARANCE FROM CAN LIGHT 7) REMOVE SCREEN FROM DRYER VENT T-TOP 8) PROVIDE 1" CLEARANCE FROM COMBUSTIBLES AT B-VENT 9) CROSS BRACING AT GABLES NOT PER PLAN |