Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/04/2004 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/28/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) INSTALL AB'S IN MASTER BEDROOM 2) DOUBLE STUDS AT OVER NOTCHED PLUMBING 3) SEAL MOISTURE BARRIER 4) LAP MOISTURE BARRIER PER CODE 5) 1/2" CLEARANCE AT CAN LIGHTS 6) NAIL PLATE CONDUCTORS AT 2 X 4 WALL WITHIN 1 1/4" OF EDGES 7) INSTALL 220V AT WATER HEATER 8) TEST WASTE 9) EXTEND 3" CO AT MB 10) NAIL PLATE WASTE 11) 1/4" PER FOOT AT LAUNDRY SINK TRAP, POWDER ROOM 12) SEAL DUCTS AT TEARS AND CONNECTIONS |
| 01/14/2004 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) LATH NOT DONE |
| 12/11/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |