Permit: T03CM04130

Parcel: 10824012A


Addresses:

2498 E RIVER RD


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T03CM04130

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
11/15/2004 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
08/27/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/PA-1)OK TO COVER Z-P 4'S WILL CHECK AAV ON FINAL
08/05/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) ABS DWV OK TO COVER SUBJECT TO LETTER FROM ARCHITECT 2) OK TO COVER #124-#128 ONLY
08/02/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*/ 1) PLUMBER NEED TO REVIEW PLANS/SPECS AND INSTALL PER PLAN, OR REVISE PLAN 2) WE HAVE IDULGED THE CONTRACTOR IN GIVING PARTIAL INSPECTIONS, BUT THINGS ARE WAY OUT OF CONTROL NOW. PLEASE HAVE ROUGH/SOIL APPROVED AT NEXT INSPECTION. NOTE: MUST BE INSTALLED PER SPECS 3) ALL PIPING TO BE SIZED ACCORDING TO ISOMETRIC. YOU MAY NOT REDUCE UNLESS YOU SEE A REDUCING TEE 4) CONTRACTOR TO PAY RE-INSPECTION FEE
07/28/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*NOT INSTALLED AS PER APPROVED PLAN. PROVIDE APPROVED REVISED PLAN ON INSTALL AS PER PLAN. ALSO COPPER UNDERGROUND AND OUT OF WALL WEHOUT(?) NOT TO CODE. PLEASE SILVER SOLDER WE DO NOT ALLOW 95-5 SOLDER UNDER SLAB. WATER UNDER SILVER PER PLAN SUPER ON JOB.
07/26/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*/ 1) NOT INSTALLED AS PER APPROVED PLAN. PLEASE INSTALL AS PER APPROVED PLAN OR PROVIDE APPROVED REVISED PLAN 2) SEE SPEC FOR SUPPORTS AND ANCHORS #1590 3) CODE VIOLATION ON WASHER BOX IN 2 HL FIRE WALL-NEED DIRECTION FROM ANCHOR ENGINEER-FOR PROPER FIRE PENETRATION CAUL SLEEVING ECT... 4) SEE SPECS FOR INSULATION ON HOTWATER PIPING
06/28/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) OK TO COVER TWO WALLS - EXTERIOR. 2) YARDWTR CORRECTION MADE OK. - OK TO COVER. 3) ROOF DRAINS OK TO COVER.
06/25/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*/ 1) SEE 606.2.2 94 UPC - FEMALE PVC SCREWED FITTINGS ARE PROHIBITED FOR WTR PIPING. 2) NO TESTS ON WTR OR ABS. REMOVE FITTINGS WITH RECTOR SEAL #5 AND REPLACE. DO NOT COVER OR CONCEAL ANY PLBG.