Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T03CM04130
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/15/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
08/27/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*/PA-1)OK TO COVER Z-P 4'S WILL CHECK AAV ON FINAL | |
08/05/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*/ 1) ABS DWV OK TO COVER SUBJECT TO LETTER FROM ARCHITECT 2) OK TO COVER #124-#128 ONLY | |
08/02/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*/ 1) PLUMBER NEED TO REVIEW PLANS/SPECS AND INSTALL PER PLAN, OR REVISE PLAN 2) WE HAVE IDULGED THE CONTRACTOR IN GIVING PARTIAL INSPECTIONS, BUT THINGS ARE WAY OUT OF CONTROL NOW. PLEASE HAVE ROUGH/SOIL APPROVED AT NEXT INSPECTION. NOTE: MUST BE INSTALLED PER SPECS 3) ALL PIPING TO BE SIZED ACCORDING TO ISOMETRIC. YOU MAY NOT REDUCE UNLESS YOU SEE A REDUCING TEE 4) CONTRACTOR TO PAY RE-INSPECTION FEE | |
07/28/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*NOT INSTALLED AS PER APPROVED PLAN. PROVIDE APPROVED REVISED PLAN ON INSTALL AS PER PLAN. ALSO COPPER UNDERGROUND AND OUT OF WALL WEHOUT(?) NOT TO CODE. PLEASE SILVER SOLDER WE DO NOT ALLOW 95-5 SOLDER UNDER SLAB. WATER UNDER SILVER PER PLAN SUPER ON JOB. | |
07/26/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*/ 1) NOT INSTALLED AS PER APPROVED PLAN. PLEASE INSTALL AS PER APPROVED PLAN OR PROVIDE APPROVED REVISED PLAN 2) SEE SPEC FOR SUPPORTS AND ANCHORS #1590 3) CODE VIOLATION ON WASHER BOX IN 2 HL FIRE WALL-NEED DIRECTION FROM ANCHOR ENGINEER-FOR PROPER FIRE PENETRATION CAUL SLEEVING ECT... 4) SEE SPECS FOR INSULATION ON HOTWATER PIPING | |
06/28/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*/ 1) OK TO COVER TWO WALLS - EXTERIOR. 2) YARDWTR CORRECTION MADE OK. - OK TO COVER. 3) ROOF DRAINS OK TO COVER. | |
06/25/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*/ 1) SEE 606.2.2 94 UPC - FEMALE PVC SCREWED FITTINGS ARE PROHIBITED FOR WTR PIPING. 2) NO TESTS ON WTR OR ABS. REMOVE FITTINGS WITH RECTOR SEAL #5 AND REPLACE. DO NOT COVER OR CONCEAL ANY PLBG. |