Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/08/2004 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 03/29/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) ADD H2.5'S AT PORCH 2) INSTALL BLOCKING AT TRUSS BEARING PER PLAN 3) INSTALL GAS BOND 4) INSTALL DRIP LEGS AT GAS APPLIANCE LINES 5) TEST WASTE LINES 6) COMPLETE WATER CLOSET 7) BOND METAL DUCTS AT BOOTS 8) PROVIDE ENGINEERING ON FIRE PLACE 9) SHIM HEADERS 10) INSTALL AB'S AT FRONT WALL AND WITHIN 12" OF JOINTS |
| 03/05/2004 |
FRAMING |
|
Not ready for Inspection |