Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/26/2004 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 03/24/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) SEVERAL ITEMS FROM PRIOR INSPECTION NOT DONE |
| 03/18/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) FIRE STOP DROP AT REAR HALLWAY (FRONT BATH DROP AT PLUMBING AND CLOSET WALL 2) SHIM HEADERS 3) FIRE STOP FURNACE PLATFORM AT CLOSET WALL 4) INSTALL TPR DRAIN AT WATER HEATER 5) SAFETY GLAZE BATH WINDOW 6) INSTALL AB AT NORTH WEST BEDROOM AND KITCHEN 7) INSTALL HEADERS AT KITCHEN AND FRONT BATH PER DETAIL 8) INSTALL HANGERS AT HIP TRUSSES 9) INSTALL ATTIC ACCESS PER CODE 10) NOT COMPLETE ENOUGH TO INSPECT |
| 03/12/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) REPAIR BLO9WN FIRE BLOCKS 2) NO TEST ON DWV'S 3) NAIL PROTECT ALL PLUMBING WITHIN 1 1/2 FROM EDGE OF STUD 4) BLOCK ALL MECH REGISTERS 5) GROUT TUBS 6) REPAIR DOUBLE TOP PLATE CUT AT LAUNDRY ROOM AND KING STUD 7) NAIL PROTECT DRYER VENT |