Permit: T03CM04081

Parcel: 12810082B

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T03CM04081

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/15/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*
10/09/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) PLEASE PROVIDE SEPARATE BACK FLOW DEVICES FOR EACH PIECE OF EQUIPMENT SERVED. ESPRESSO AND COFFEE MACHINE EACH REQUIRE SEP. BACKFLOW PROTECTION. CAN BE 007. 2) INLET TO ICE MACHINE BACKFLOW DEVICE SHALL BE SAME SIZE AS UNIT SERVED. 3) ALL INDIRECT WASTE PIPING SHALL TERMINATE AT LEAST 1" ABOVE FLOOR SINKS. 4) ICE BIN STORAGE DRAIN REQUIRES CLEAN OUT AND PROPER SUPPORT. 5) WOMENS RESTROOM H/C STOOL TO HAVE FLUSH HANDLE ON WIDE SIDE OF ROOM. 6) LAVS IN RESTROOMS TO HAVE H/C DRAIN AND HOT SUPPLY INSULATION COVERS.
09/19/2003 PLUMBING - FINAL Not ready for Inspection