Inspection Status: Approved
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/20/2003 |
ROOF NAILING |
|
Approved |
IVRS - Inspection 0000* |
| 11/18/2003 |
ROOF NAILING |
|
Denied |
IVRS - Inspection 0999*/ 1) STRAP NON OVERLAPPING DBLE TOP PLATES AT ALL CORNERS AND PLATE BREAKS. 2) O.S.B. NOT NAILED BY KITCHEN. 3) PORCH BEAM SUPPORTING POST NOT ANCHORED AND REQUIRES 4X6 POST. 4) X BRACE GABLE END TRUSSES - EACH END AND EVERY 25'. 5) 4/52 NOT COMPLIED WITH AT 4' O.C. 6) PROVIDE COLLAR TIES ST OVERBUILD AREA AT 4' O.C. 7) 4 GIRDER TRUSS MUST HAVE 4 STUDS UNDER EACH END. 8) CLIP OVERFRAME ROOF RAFTERS TO ROOF STRUCTURE. 9) PROVIDE 22X30 ACCESS TO OVERFRAMED AREA. 10) GARAGE OPENINGS REQUIRE 6X6 POSTS. 11) 6/52 NOT COMPLIED WITH. 12) ONE AREA OF ROOF NOT NAILED. |