Permit: T03CM04011

Parcel: 138243430

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
12/11/2003 BUILDING - FINAL Approved IVRS - Inspection 0000*
12/10/2003 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) NO CHANGE
12/08/2003 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) WHITE CONDUCTOR NOT ALLOWED TO BE HOT IN ELECTRIC PANEL 2) A/C CIRCUIT BREAKER ALUMINIUM CONDUCTOR REQUIRES ANTI-CORROSIVE GREASE AND ALUMINIUM GROUNDS REQUIRE ANTI-CORROSIVE GREASE 3) 1" CLEARANCE REQUIRED TO COMBUSTIBLES FOR FURNACE "B" VENT 4) ATTIC SWITCH COVER BROKEN 5) BATHROOM GFCI HOT WHEN TRIPPED