Permit: T03CM04008

Parcel: 124050890


Addresses:

725 E 5TH ST #04


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T03CM04008

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
09/28/2004 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
09/24/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
02/10/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*
02/06/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*
01/30/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*/ 1) PLUMBING IS NOT PER PLAN BUILD TO PLAN OR REVISE PLAN TO AS BUILT AND APPROVED BY CITY 2) TUB IS NOT PROPERLY VENTED MUST VENT WITHIN 60" OF TRAP ON 2" DRAIN PRESENTLY 71" TO VENT 3) FLAT VENT MUST CONNECT ABOVE THE CENTER LINE OF CONNECTING DRAIN