Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/17/2004 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 05/14/2004 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) CLAMP DAMPER OPEN |
|
| 05/10/2004 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NEED STUCCO, INSULATION AND DOUBLE STAMPED POST TENSION CERTS 2) LABEL BREAKER #10 3) NEED POST TENSION TAG ON HOSE BIB 4) FIRE CAULK GAS LINE PROTRUSION IN FIREPLACE AND CLAMP DAMPER OPEN 5) NO OUTLETS ARE ALLOWED UNDER A COUNTER WITH GREATER THAN A 6" OVER HANG 6) SEAL TOILETS TO FLOOR 7) RAISE DISHWASHER DRAIN TO COUNTER BOTTOM |