Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
09/19/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
09/17/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) CLIP GLUE LAM HEADER TO KING STUDS 2) SECOND FLOOR STRAP AT SOUTH WEST CORNER MUST EXTEND TO HEADER 3) DOUBLE TOP PLATES MUST BE CONTINOUS AT SHEAR WALL SOUTH WALL. PROVIDE ENGINEER APPROVED REPAIR 4) ALL PLATE SPLICES MUST BEAR ON STRUCTURAL MEMBERS 5) HOLDOWNS LOOSE BOLTS
09/15/2003 EXT METAL CLIPS/EXT SHEATHING Denied 1) H.D. MISSING NUTS 2) CLIP HEADER GLB 3) SW5 NOT NAILED CORNER 4) 2ND FLOOR STRAP WRONG LOCATION 5) PROVIDE CONTINOUS POST FROM DOUBLE GIRDER TRUSS 6) CLIP CORNER POST 7) GLUE LAM BEAM NOT PROPERLY SUPPORTED. REMOVE FILLER