Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/19/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 09/17/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) CLIP GLUE LAM HEADER TO KING STUDS 2) SECOND FLOOR STRAP AT SOUTH WEST CORNER MUST EXTEND TO HEADER 3) DOUBLE TOP PLATES MUST BE CONTINOUS AT SHEAR WALL SOUTH WALL. PROVIDE ENGINEER APPROVED REPAIR 4) ALL PLATE SPLICES MUST BEAR ON STRUCTURAL MEMBERS 5) HOLDOWNS LOOSE BOLTS |
| 09/15/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
1) H.D. MISSING NUTS 2) CLIP HEADER GLB 3) SW5 NOT NAILED CORNER 4) 2ND FLOOR STRAP WRONG LOCATION 5) PROVIDE CONTINOUS POST FROM DOUBLE GIRDER TRUSS 6) CLIP CORNER POST 7) GLUE LAM BEAM NOT PROPERLY SUPPORTED. REMOVE FILLER |