Inspection History: FRAMING
Permit Number - T03CM03980
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/02/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
12/01/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) OVER SPAN AT GARAGE 2) FIRE BLOCK MISSING AT WATER HEATER AREA 3) SECURE ROMEX WITHIN 8" FROM BOX 4) NAIL PROTECT DRYER VENT 5) NAIL PROTECT ELECTRICAL WITHIN 1 1/4" FROM EDGE OF STUD 6) LOOSE ANCHOR BOLTS THROUGHOUT 7) SEAL MOISTURE BARRIERS 8) BLOWN FIRE BLOCKS AT KITCHEN |