Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM03980
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/10/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
11/06/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) DAMAGED STUD WEST WALL, NOT NAILED TO BANG PLATE 2) CHECK NAIL SIZE IN STHD 3) NAIL HORIZONTAL JOINTS REAR 1ST FLOOR SHEAR 4) 2/SD2 6-12 ON CENTER 5) NAIL REAR WALL TO TRUSS PER 7/SD3 1 1/2" GAP 6) BETWEEN TRUSS CHORD AND RAKE WALL TOP PLATE 6) NAIL OFF WIND BRACE EAST WALL 7) ADD WIND BRACE FRONT 2ND FLOOR 8) NAIL OFF ROOF DECK SMALL BROW ROOF FRONT AT 1ST RAFTER 9) ADD BLOCKS AT FRONT TO SUPPORT OSB 10) FLAT STRAP FRONT TRUSSES GARAGE TO BEAM 11) TIE GARAGE BEAM TO 2 X 10 HEADER FIX CRACK WITH SCAB |