Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 09/04/2003 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000* |
| 09/03/2003 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) NO WATER TEST (10' HEAD) 2) SEE LAST REJECTION AND COMPLY |
| 08/29/2003 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) SEWER LINE CANNOT BE SUPPORTED ON ROCK. SEE UPC 718.2. HAVE SHADE MATERIAL ON SITE FOR COVER AFTER ALL ROCK IS REMOVED AND SEWER DRAIN IS INSPECTED. 2) SEWER LINE CANNOT BE BRIDGED. 3) UNCOVER ALL FITTINGS AND CONNECTORS. |