Permit: T03CM03961

Parcel: 136074960

Inspection Status: Denied

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/03/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) SEE PRIOR INSPECTION
10/03/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
09/25/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) CLIP GABLES TO TOP PLATES 2) BLOCKS REQUIRED BETWEEN TRUSSES AND NAILED TO PLY AT ENTRY DOOR 3) HANGER MISSING AT HIP TRUSS 4) BLOCK PLY AT VALLEY 5) CLIP TRUSSES AT 2 X 6 INT. BEARING 6) RECHECK ROOF NAILING 7) DOUBLE STUDS REQUIRED UNDER DOUBLE GIRDER TRUSS
09/24/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) NOT READY FOR INSPECTION, CANCELLED