Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM03950
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/17/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
09/11/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) TRUSS BRACE RAT RUNS NOT PER A1 AND A2 2) 3/DT1 NOT COMPLIED WITH AT SHEAR WALLS 3) HEADERS MUST BEAR ON TRIMMERS AND TOP PLATE BEAR ON HEADERS 4) #5 SHEAR WALL NOT NAILED TO STUDS 5) HINGE BRACES NOT NAILED THRU SHEATHING PER 6/DT1 6) OSB PANELS MUST SPAN TWO BAYS (THREE TRUSSES) PANEL TO SMALL | |
09/09/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) TRUSS BH DOES NOT MATCH CALC 2) TRUSS BH1 DOES NOT MATCH CALC 3) TRUSS A2 DOES NOT MATCH CALC 4) TRUSS A1 DOES NOT MATCH CALC 5) TRUSS A DOES NOT MATCH CALC 5) RETRO HOLDOWNS AT TRIMMERS | |
09/08/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0145*/ 1) INSTALL MASTER 48'S AT GARAGE 2) RETRO HOLDOWNS AT TRIMMERS 3) SHIM HEADERS THROUGHOUT 4) NAIL GARAGE KINGS PER DETAIL 5) NO TRUSS CALC'S 6) COMPLETE DETAIL #3 DT-1 | |
09/05/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999* |