Permit: T03CM03864

Parcel: 116093810


Addresses:

893 N LEUTEA DR

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
05/06/2004 BUILDING - FINAL Approved IVRS - Inspection :*
04/28/2004 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
04/05/2004 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) PROVIDE ACCESS TO JACCUZI PUMP FOR MAINTANCE AND REMOVAL 2) BEDROOM WINDOWS CANNOT EGRESS INTO POOL ENCLOSURE 3) GAS NOT CONNECTED TO SOUTH FURNACE 4) SOUTH 'B' VENT PLUGGED WITH TAPE 5) BATHROOM WINDOWS IN WET AREA WITHIN 60" ELEVATION OF TUB DRAIN MUST BE SAFETY GLAZED 6) NO ACCESS TO SOUTH MECH ROOM 7) PROVIDE STUCCO INSULATION CERTIFICATE 8) WHERE IS JACCUZI GFCI ?
04/02/2004 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) NOT READY, CANCELLED
03/19/2004 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) SAFETY GLAZE SERVICE DOOR LANDING 2) MAKE-UP DISCONNECTS 3) HAND RAIL EGRESS AT POOL FROM B.R. 4) SEAL BOTTOM OF SERVICE PANEL 5) SEPARATE GFI AT JACUZZI LIVING ROOM AND HALL OUTLETS 6) BACKFLOWS AT EXTERIOR TAPS 7) PROVIDE ACCESS TO JACUZZI FURNACE AND WATER HEATER FLUES
03/18/2004 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) COMPLETE GRADING 2) INSTALL HANDRAIL AT STEPS 3) STAIRS DO NOT MEET CODE 4) EXPOSED WIRING AT EXTERIOR 5) STOPPED NOT A COMPLETE INSPECTION 6) TOO MANY ITEMS TO LIST