Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/12/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 12/11/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) SHIM HEADERS 2) DOUBLE OVERNOTCHED STUDS 3) SECURE ABS 4) SEAL MOISTURE BARRIER AND PYRO-GARD 5) SAFETY GLAZE HALL BATH 6) NAIL PLATE AT KITCHEN AND REPAIR CONDUCTOR TO PORCH FAN THROUGHOUT 7) NAIL PALTE WATER WITHIN 1 1/4" OF STUD EDGE 8) 1" CLEARANCE AT FURNACE FLU 9) SEAL COPPER TO ATTIC 10) NAIL PLATE VACCUM LINE 11) REPLACE STUD NEAR FIREPLACE 12) INSTALL SHEAR AT NORTH 13) COMPLETE STUCCO MESH |
| 11/06/2003 |
FRAMING |
|
Cancelled |
IVRS - Ri canceled |
| 11/03/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NO PLAN OR PERMIT ON SITE 2) EXTERIOR SHEATHING AND CLIPS HAVE NOT BEEN APPROVED 3) PRIOR TO NEXT INSPECTION WE NEED CORRECTION ON STREET NAME |