Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 04/09/2004 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 04/05/2004 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) ACCESS TO AC CONDENSOR DISCONNECT OBSTRUCTED BY UNIT MUST HAVE 30" X 30" UNOBSTRUCTED WORK AREA 4) PROVIDE ACCESS TO JACCUZI TUB PUMP 5) ELECTRIC GFCI OUTLET REQUIRED WITHIN 24" OF KITCHEN SINK RT SIDE 6) SAFETY GLAZING REQUIRED FOR WINDOWS IN TUB WET AREA BELOW 60" ON TUB DRAIN 7) JACCUZI OUTLET HAS BEAR WIRES AND NO GFCI 8) NORTH WATER HEATER MISISNG VENT 9) PROVIDE INSULATION AND STUCCO INSTALLATION CERTIFICATE |
| 03/19/2004 |
BUILDING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) CANCELLED |