Permit: T03CM03863

Parcel: 116093800


Addresses:

911 N LEUTEA DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/05/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
10/17/2003 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000* 1) PROVIDE TRUSS CALC'S 2) OK TO COVER ROOF
10/16/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0145*/ 1) RECALL
10/14/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) OVERSPAN OF DOUBLE TOP PLATE ABOVE HEADERS FOR WINDOWS IN GARAGE. ADD CRIPPLE STUDS 2) OSB ROOF SHEATHING MUST BE APPLIED WITH GRAIN PERPENDICULAR TO TRUSSES 4 PANELS 3) LEDGER BUTT SPLICES MUST OCCUR ON STRUCTURAL MEMBERS 4) NO CITY APPROVED TRUSS DRAWINGS ON SITE 5) PROVIDE LEDGER DETAIL THAT IS NOT SHOWN ON 3/D2 6) PROVIDE SHEAR PANEL DETAILS TO INCLUDE TYPE OF MATERIAL NAIL SIZE AND NAIL PATERN AS WELL AS HOLDOWN REQUIREMENT 7) SHEAR MUST BE NAILED AT ALL EDGES AND SEAMS AND TO ALL SUPPORTING STUDS 8) SUPPORTING POSTS MUST EQUAL WIDTH OF BEAM SUPPORTED 9) ONE ROOF PANEL NOT NAILED