Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM03859
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/23/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
09/22/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) GARAGE COLUMN (MIDDLE) MAS NOT NAILED NAIL IN CRACK HAVE NO VALUE 2) NAIL OFF ALL MAS ANCHORS SIX NAILS EACH H.D. 3) STRAP REAR PORCH BEAM 4) TWO NAILS IN EACH WIND BRACE TOP/BOTTOM PLATE 5) FINISH NAILING OFF ROOF 6) LATERAL BRACE R-4 TRUSS R4G PER SHOP DRAWINGS 7) PRESSURE/LATERAL BLOCKS NOT NAILED TO ROOF 9/D1 | |
09/19/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) TRUSS CROSS BRACES NAIL TO RIDGE BLOCK OR CONNECT WITH H2.5 2) ROOF NAIL NAILED, NAILS REQUIRED AT PRESSURE LATERAL BLOCKS ABOVE BEARING WALL 3) ALL MAS TO HAVE 2 NAILS EACH SIDE, IF NAILS ARE AT AN ANGLE DON'T USE TECO #10 USE 10D FRAMING NAIL 4) BLOCKS COVERING HOLSE NAIL TO SHEATHING 5) 2 NAIL REQUIRED IN WIND BRACE AT PLATES 6) WRONG NAILS USED IN HANGER 7) GARAGE LEAK TRUSS DRAWINGS | |
09/17/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NOT READY, SAME AS LAST INSPECTION PER SUPER |