Permit: T03CM03835

Parcel: 14027045A


Addresses:

2621 E GINTER RD

Inspection Status: Approved

Inspection History: ELECTRIC - CABLE DROP

Date Description Inspector Results Comments
07/13/2004 ELECTRIC - CABLE DROP Approved IVRS - Inspection :*
03/04/2004 ELECTRIC - CABLE DROP Denied IVRS - Inspection 0245* / 1) INSTALL A PERMANENET ADDRESS LABEL, SCREWED OR RIVITED TO ENCLOSURE. 2) INSTALL BOND BUSHING AT SERVICE NIPPLE BOTH SIDES, AND RISER CONDUIT. 3) GROUND 12X12 J-BOX, USE APPROVED FITTINGS, REDUCING WASHERS, BUSHINGS ETC. 4) BOND BLDG STEEL, COLD WATER PIPING TO SERVICE GROUNDING ELECTRODE SYSTEM. 5) SUPPORT CONDUIT WITHIN 3' OF TERMINATIONS, EVERY 10'. 6) INSTALL GROUND TAILS IN METAL BOXES THRU OUT. 7) 6" of make-up conductors in each device box. 8)PLUG ALL UNUSED OPENINGS IN BOXES, FIXTURES.
03/03/2004 ELECTRIC - CABLE DROP Denied IVRS - Inspection 0920*