Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM03807

Parcel: 10819008G


Addresses:

4558 N 1ST AV #110


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T03CM03807

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
11/07/2003 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*/ 1) ABS DWV UNDERGROUND OK. WATER TEST RISER TO TEN FEET. 2) PLUMBER PLEASE NOTE: A HUSKEE BAND IS NOT AN APPROVED COUPLING FOR ABS. IN THE FUTURE USE CORRECT TRANSITION COUPLING. 3) OK TO BACKFILL.