Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 12/12/2003 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 12/11/2003 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0935*/ 1) ALUMINUM CONDUCTORS REQUIRE ANTI-COROSSIVE COMPOUND REPEAT REFEE 2) ALUMINUM CONNECTORS LOOSE-NOT TORQUED 3) EXPOSE GROUND RODS |
| 12/08/2003 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) WHITE CONDUCTORS CANNOT BE HOT 2) ANTI-CORROSIVE GREASE REQUIRED ON ALUMINUM CONDUCTORS 3) ALUMINIUM WIRES DAMAGED NICKED-MAKE CORRECTIONS 4) ALL OUTLETS IN GARAGE MUST BE GFCI PROTECTION 5) NO GROUND ON HOUSE-INSTALL GROUND RODS 6) TRUSS BY FURNACE "B" VENT CUT. PROVIDE ENGINEERS APPROVED REPAIR 7) NO INSULATION UNDER FURNACE PLATFORM |
| 12/05/2003 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) INSULATION CO. 2) INSULATION ? ATTIC |
| 12/04/2003 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) ELECTRIC SERVICE PANEL DOOR HINGE BROKEN 2) NO ACCESS TO ATTIC FUR |