Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/16/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 10/15/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 10/14/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PEX STAPLED AT ENTRANCE 2) ANCHOR BOLTS REQUIRED WITHIN 12" OF SPLICES 3) ? 1/2" GAS LINE AT 6' ON CENTER NOT AT FITTING 4) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF SURFACE 5) WATER EVERYWHERE. DRY UP ALL WATER 6) FLOOR JOIST OVERSAPN 7) PROVIDE PANTRY TRANSFER 8) BLOCK DEFUSERS 3 SIDES 9) FIRE BLOCK STOP W/H VENT 10) SEAL VAPOR BARRIER PENETRATIONS 11) SECURE FLOOR FLANGES |