Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T03CM03799
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/04/2009 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
12/03/2008 | PLUMBING - FINAL | Not ready for Inspection | 1. CLEANOUT IS BURIED AND OR THE SIDEWALK 2. REPAIR HOLE THRU FOUNDATION AT SEWER CONNECTION 3. NO POWER TO WATER HEATER 4. SILL COCK IS TO BE FLUSH WITH EXTERIOR WALL |
|
06/09/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. YOU MUST COVER THE ABS IMMEDIATELY LONG TERM EXPOSURE TO ULTRAVIOLET LIGHT IS DETRIMENTAL TO ABS AND MAY REQUIRE YOU TO REMOVE DAMAGED SECTIONS AND REPLACE WITH UNAFFECTED PIPE. 2. NO INSULATION KIT ON LAVATORY 3. NO INSULATION ON FIRST EIGHT FEET OF HOT AND COLD AT WATER HEATER 4. WHERE IS THE CLEANOUT UNDER THE SINK? |