Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - YARD WTR LINE/TEST
Permit Number - T03CM03799
Inspection Description - PLUMBING - YARD WTR LINE/TEST
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/04/2007 | PLUMBING - YARD WTR LINE/TEST | Approved | IVRS - Inspection :* OK TO COVER YARDWATER OK TO COVER SEWER |
|
09/26/2007 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :* 1. NO CHANGE FROM LAST INSPECTION 2. CONTINUED NOT READY WILL RESULT IN A REINSPECTION FEE |
|
08/02/2007 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :* - WHERE IS RPPBP? - EXPOSE ALL PIPE AND FITTINGS - INSTALL AVB ON HOSE BIBB - ALL PIPING IS TO BE LAID ON A FIRM BED (REMOVE TRASH AND DEBRIS) AND SHADED WITH CLEAN FILL - TWO WAY CLEANOUT FITTING IS NOT APPROPRIATE AT THAT LOCATION - CLEANOUTS SHALL OPEN IN THE DIRECTION OF FLOW - "EXISTING" CLEANOUT IS MISSING |