Permit: T03CM03799

Parcel: 117042400


Addresses:

529 N 6TH AV


Inspection Status: Approved

Inspection History: PLUMBING - YARD WTR LINE/TEST

Permit Number - T03CM03799

Inspection Description - PLUMBING - YARD WTR LINE/TEST

Inspection Status - Approved

Date Description Inspector Results Comments
10/04/2007 PLUMBING - YARD WTR LINE/TEST Approved IVRS - Inspection :*
OK TO COVER YARDWATER
OK TO COVER SEWER
09/26/2007 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection :*
1. NO CHANGE FROM LAST INSPECTION
2. CONTINUED NOT READY WILL RESULT IN A REINSPECTION FEE
08/02/2007 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection :*
- WHERE IS RPPBP?
- EXPOSE ALL PIPE AND FITTINGS
- INSTALL AVB ON HOSE BIBB
- ALL PIPING IS TO BE LAID ON A FIRM BED
(REMOVE TRASH AND DEBRIS) AND SHADED WITH CLEAN FILL
- TWO WAY CLEANOUT FITTING IS NOT APPROPRIATE AT THAT LOCATION
- CLEANOUTS SHALL OPEN IN THE DIRECTION OF FLOW
- "EXISTING" CLEANOUT IS MISSING