Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: MECHANICAL - ABOVE CEILING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/24/2003 |
MECHANICAL - ABOVE CEILING |
|
Approved |
IVRS - Inspection 0000* |
| 10/06/2003 |
MECHANICAL - ABOVE CEILING |
|
Partial Approval |
IVRS - Inspection 0000* |
| 09/17/2003 |
MECHANICAL - ABOVE CEILING |
|
Denied |
IVRS - Inspection 0999*/ TERMINATE BATHROOM EXHAUST THRU THE ROOF, 1ST FLOOR. PROVIDE BACKING AROUND CEILING AND SIDE WALL BOXES. SEAL ALL JOINTS ON METAL DUCT. YOU CANNOT CUT A HOLE IN FLEX DUCT AND MAKE A BOX OUT OF IT. PROVIDE SHEET METAL, INSULATED, CEILING BOXES ON 2ND FLOOR. TERMINATE ALL CONDENSATE DRAINS TO AN APPROVED LOCATION. PLEASE PROVIDE PLANS AND PERMITS FOR ALL PLUMBING WORK BEING DONE PRIOR TO NEXT INSPECTIONS. |