Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM03767
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/23/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
10/22/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) ADD SHEAR PANEL AT PATIO DOOR OR INSTALL APPROVED. ALTERNATE HD AT END OF 12' SHEAR PANEL 2) STRAP TOP PLATES WHERE NOT LAPPED 24" 3) NAIL 2ND FLOOR BOTTOM PLATES AT 12" ON CENTER AT SHEAR WALLS |