Permit: T03CM03722

Parcel: 10409001C


Addresses:

4365 N ORACLE RD


Inspection Status: Approved

Inspection History: PLUMBING - YARD WTR LINE/TEST

Permit Number - T03CM03722

Inspection Description - PLUMBING - YARD WTR LINE/TEST

Inspection Status - Approved

Date Description Inspector Results Comments
01/21/2004 PLUMBING - YARD WTR LINE/TEST Approved IVRS - Inspection 0000*/ 1) CONTRACTOR REMOVED COMPRESSION COUPLINGS - INSTALLED SWEAT COUPLINGS. 2) YARDWATER OK FROM METER THRU RPPBP AND CONNECTED AT BLDG. OK TO COVER
01/13/2004 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection 0000*/ 1) 1½" TYPE 'K' SOFT LOOPED FROM RPPBP TO BLDG WITH COMPRESSION COUPLINGS. OK TO COVER SUBJECT TO ARCHETECTS APPROVAL OF COUPLINGS.
01/12/2004 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection 0000*
12/15/2003 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection 0000*/ YARD WTR STUBBED UNDER SLAB AND UP INSIDE BLDG OK. PRESSURE TEST OK. OK TO COVER.