Permit: T03CM03719

Parcel: 140374060


Addresses:

6179 E STONECHAT DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/11/2003 FRAMING Approved IVRS - Inspection 0000*
12/09/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) ITEMS FROM PREVIOUS INSPECTION NOT CORRECTED
12/04/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) NAIL PROTECT ELECTRIC WITHIN 1 1/4" FROM EDGE OF STUD AT STAIR AREA 2) B-VENT FOR WATER HEATER NOT TERMINATED THROUGH ROOF
11/26/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) FLAT ROMEX NOT ALLOWED TO BE STAPLED ON IT'S SIDE 2) WATER LINES IN GARAGE HANGING BELOW CEILING 3) HOLDOWNS AT GARAGE SHEAR WALL MISSING BULB 4) DUCT IN DINING ROOM AREA HANGING BELOW CEILING 5) FIRE BLOCK MISSING AT RIGHT SIDE OF PONY WALL ABOVE 6) COMPLKY WITH DETAIL 54AD'S STAIR AT CONCRETE FLOOR 7) STOPPED INSPECTION TO MANY ITEMS