Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
Permit Number - T03CM03706
Inspection Description - ROOF NAILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/15/2003 | ROOF NAILING | Approved | IVRS - Inspection 0000* | |
09/11/2003 | ROOF NAILING | Not ready for Inspection | IVRS - Inspection 0000*/ GARAGE: 1) RENAIL ROOF DECK TO LEDGER WITH 8D'S AT SOUTH WALL. 2) H2.5 REQUIRED AT LEDGERS AT ALL FOUR WALLS TAB A3.5 WASN'T BENT OVER LEDGER AND NAILED. 3) BOTTOM PLATE TO OSB SHEAR SOUTH WALL MISSING. 4) P.T. CABLES NOT PULLED. / HOUSE: 1) FINISH SHEAR, NORTH WALL NAIL P.A. 2) A.B.B. PLATE REAR PORCH (BEAM). 3) MISSING PERIMETER NAILING NORTH WALL SHINERS, RENAIL (MARRED IN BLACK ROOF. 4) MISSING NAILS IN P.A. STRAPS. 5) FRONT PORCH STRAP ROUGH SAWN GW LAM TO WALL (FOR WITH DRAW END PIECE). 6) MISSING H2.5 FRONT ENTRY TRUSS. 7) NEED P.T. CABLES PULLED. |