Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/28/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 08/27/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) BANG PLATES MISSING |
| 08/26/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0145*/ 1) NAIL PLATE PLUMBING 2) STRAP CORNER NOT CABIN TIED 3) OVER NOTCHED STUDS 4) ADD STUD AT GARAGE WATER LINE 5) NAIL SHEAR A BLOCKING 6) 4" NAIL SPACING AT SHEAR 6 7) STRAP FRONT GABLE 8) STRAP WHERE NOT CABIN TIED 9) CONTINOUS DOUBLE PLATE AT GARAGE DRAG 10) SOLID BEARING AT GABLE TRUSS 11) RETRO FIT HOLDOWNS 12) NOT A COMPLETE INSPECTION |