Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM03692
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/13/2004 | FRAMING | Approved | IVRS - Inspection 0000* | |
01/12/2004 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) COMPLY WITH DETAIL SD-4/10, 12 AND 16 | |
01/07/2004 | FRAMING | Denied | IVRS - Inspection 0999* REJ SAME AS BEFORE | |
12/30/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) CHECK ALL INTERSECTING SHEARWALL FOR PROPER NAILING S/D-4 10/12/16 2) PROBLEM W/COMB AND RELIEF TERMINATION IN ATTIC | |
12/22/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) B VENT UPSTAIRS 2) CHECK ELECTRIC THRU-OUT FOR 1 1/4" CLEAR FROM FACE OF STUD | |
12/19/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) 1" CLEARANCE REQUIRED FROM "B" VENT TO WOOD 2) NAIL PROTECT ELECTRIC < 1 1/4" FROM FACE OF FRAMING |