Permit: T03CM03687

Parcel: 13355231A

Inspection Status: Approved

Inspection History: PLUMBING - YARD WTR LINE/TEST

Permit Number - T03CM03687

Inspection Description - PLUMBING - YARD WTR LINE/TEST

Inspection Status - Approved

Date Description Inspector Results Comments
06/09/2004 PLUMBING - YARD WTR LINE/TEST Approved IVRS - Inspection :*
03/15/2004 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection 0000*/ LINE PRESSURE ON TWO 1½" COPPER LINES FROM METER THRU 1½" BACKFLOW PROTECTION DEVICES TIEING INTO 2" BLDG SERVICES OK. PENDING CITY APPROVED DRAWING SHOWING 1½" PIPING AND BACKFLOW DEVICES IS OK.
03/11/2004 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection 0000*/ 1) EXPOSE YARD WTR PIPING. 2) NO INTERMINGLING OF GALV. PIPING ON COPPER H2O SYSTEM. MUST USE DIELECTRIC FITTINGS.