Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/04/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 11/13/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) FIRE BLOCKS MISSING AT STAIR LANDING 2) OK TO INSULATE 3) PARTIAL 2035 DUE TO 16" BREAKFAST BAR OVERHANG WITH OUTLET UNDERNEATH REMOVE OUTLET, NOT ALLOWED WHEN BAR EXTENDS MORE THAN 6" |
| 11/10/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) FIREBLOCK MISSING AT WATER HEATER STAND 2) TOP THREE STAIR TREADS NOT NAILED 3) ELECTRICAL WIRE IN SOUTH EAST BEDROOM NEEDS TO BE RE-ROUTED 4) PROVIDE 1" CLEARANCE FROM COMBUSTIBLES AT WATER HEATER FLUE THROUGH ROOF 5) FIRE BLOCKS MISSING AT STAIR LANDING |
| 11/07/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) FIRE BLOCK MISSING AT WATER HEATER PLATFORM 2) ELECTRICAL BOX IN KITCHEN NOT INSTALLED OR MADE UP JUST HANGING 3) FIRE BLOCKS MISSING AT STAIR LANDING 4) LOOSE STEPS NOT NAILED 5) NO TEST ON 2ND FLOOR AB'S 6) PROVIDE 1" CLEARANCE FROM COMBUSTIBLES AT WATER HEATER FLUE 7) MOVE ELECTRIC WIRES AWAY FROM GUSSETT PLATES 8) CLIP LANDING FROM UNDER NORTH 9) HOLDOWN MISSING BOLT |
| 11/05/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |