Permit: T03CM03662

Parcel: 129020960


Addresses:

207 S EASTBOURNE AV


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM03662

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/16/2003 FRAMING Approved IVRS - Inspection 0000*
11/19/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) 2 X 10'S AT 24" ON CENTER OK 2) 2 X 8'S USED AT 24" ON CENTER, NOT ALLOWED 3) 2 X 8'S AT 16" ON CENTER OK