Permit: T03CM03661

Parcel: 14025084B


Addresses:

5945 S JEANETTE BL

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/18/2005 FRAMING Approved IVRS - Inspection :*
01/12/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REAR PORCH BEAMS TO BE 6 X 8 PER PLAN
2) INSTALL GABLE END VENTS
3) PLANS CALLS FOR 1" GAS LINE TO RANGE, 3/4" TO H20 HEATER
4) GROUND ALL METAL ELECTRIC BOXES
5) INSTALL PORCH ELECTRIC BOXES
6) NO TEST DWV
7) INSTALL BANG PLATES PLUMBING AND ELECTRIC THROUGHOUT
8) DRYER EXHAUST VENT TO BE 4" DIAMETER PER PLAN
9) PROVIDE COMBUSTION AND RELIEF MECHANICAL VENTS H20 HEATER MINIMUM 100 SQUARE INCH TOP AND BOTTOM
10) COMPLETE ALL TO PALN/CODE AND RECALL
11) STOPPED INSPECTION