Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T03CM03650
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/04/2003 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
08/28/2003 | BUILDING - FINAL | Denied | IVRS - Inspection 0999* | |
08/26/2003 | BUILDING - FINAL | Partial Approval | IVRS - Inspection 0000*/ 1) LAUNDRY AND BATH VENT INCOMPLETE AND PAINT LATEX 2) INSTALL GROUND ROD AND CONDUCTOR SUB-PANEL 3) PLUG ELECTRIC PANEL KNOCKOUTS 4) GAS PIPING HOLDING PRESSURE INSIDE, CONNECT PIPING TO METER AND RETEST | |
07/30/2003 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/ 1) LAUNDRY DRAIN NOT VENTED 2) ALL KITCHEN COUNTER OUTLETS MUST BE GFCI PROTECTED. GFCI OUTLET WIRED INCORRECTLY-HOT WHEN TRIPPED 3) ALL COUNTER SPACES GREATER THAN 12" REQUIRE GFCI OUTLET 4) BATHROOM LAV NOT VENTED 5) W/H "B" VENT REQUIRES 1" TO COMBUSTIBLES 6) PROVIDE 100 SQUARE HIGH AND LOW COMBUSTION AIR FOR WATER HEATER 7) W/H T & P MUST EXHAUST OUTSIDE 3/4 LINE EXHAUST DOWN 8) HOUSE REQUIRES 2 DEDICATED CIRCUIT BASE BOARD HEATERS 9) LABEL ALL CIRCUITS IN ELECTRIC PANEL FILL KOS 10) BEDROOM REQUIRES SMOKE DETECTOR 11) GAS LINE MUST BE 12" BELOW OR 6" ABOVE GRADE. PROVIDE 10 PSI MINIMUM GAS PRESSURE TEST |