Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM03639

Parcel: 110031650

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM03639

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
10/23/2003 FRAMING Approved IVRS - Inspection 0000*
10/21/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) BANG PLATE SOME OF THE HOME RUNS AT TOP PLATE 2) BANG PLATE PRIMARY CONDENSATE AT TOP PLATE 3) FINISH SECONDARY CONDENSATE TO EXTERIOR 4) SECURE WIRES IN CEILING AT KITCHEN GAS PIPE 5) BANG PLATE WIRES AT KITCHEN TOP PLATES 6) SHIM HEADERS WHERE NEEDED 7) REMOVE STAPLES BEHIND HOME RUNS 8) WATER AND DWV OK