Permit: T03CM03622

Parcel: 141175880

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM03622

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
09/15/2003 FRAMING Approved IVRS - Inspection 0000*
09/12/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) MAS STRAPS NOT NAILED NEED TO SEE 4 NAILS 2) RENAIL GUSSET AT TRUSS LIVING ROOM 3) BANG PLATE ROMEX REAR WALL 4) FIX STUD AT TUB 5) TIGHTEN HD NUTS 6) STRAP DRYER 7) POSITIVE PITCH ON 2" VENT MIDDLE BATH