Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/15/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 09/12/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) MAS STRAPS NOT NAILED NEED TO SEE 4 NAILS 2) RENAIL GUSSET AT TRUSS LIVING ROOM 3) BANG PLATE ROMEX REAR WALL 4) FIX STUD AT TUB 5) TIGHTEN HD NUTS 6) STRAP DRYER 7) POSITIVE PITCH ON 2" VENT MIDDLE BATH |