Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date |
Description |
Inspector |
Results |
Comments |
| 06/17/2004 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Approved |
|
| 10/03/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*/ 1) BED JOINTS ARE IN EXCESS OF MAXIMUM ALLOWABLE 2) SOME BEDS ARE AS MUCH AS 2" OR MORE |
| 09/28/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) GARAGE PERIMETER FOOTINGS 2) PORCH PERIMETER FOOTINGS 3) GAZEBO PIERS 4) NOTE: DOES NOT INCLUDE TOE DOWNS |
| 09/22/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*/ 1) GAZEBO: 12" BELOW GRADE AT PIER FOOTINGS FOR GAZEBO 2) 3" CLEARANCE AT SOIL TO STEEL 3) 10" TOE DOWN NOT INSTALLED PORCH: 1) 3" CLEARANCE AT SOIL TO STEEL 2) F4 NOT INSTALLED 3) INSTALL DOWELS AND PROVIDE SPECIAL INSPECTION REPORT GARAGE: 1) F6 NOT INSTALLED 2) 3" CLEARANCE AT SOIL TO STEEL 3) F2 NOT INSTALLED |