Permit: T03CM03591

Parcel: 116035330


Addresses:

1577 N PAINE CT

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/03/2003 FRAMING Approved IVRS - Inspection 0000*
10/02/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) NAIL PLATE MASTER BATH 2) GROUT TUBS 3) NAIL PLATE IN GARAGE NEAR EXTERIOR, WALK THROUGH, MASTER BEDROOM AND BATH 4) 1/2" AIR SPACE AT CAN LIGHTS 5) SECURE HOLDOWNS AT INTERIOR 6) 4" EDGE NAILING AT SHEAR JOINTS IN GARAGE 7) LOAD ROOF 8) NOT A COMPLETE INSPECTION, RECALL WHEN READY
09/30/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) CANCELLED