Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM03590

Parcel: 116036000


Addresses:

2363 W DILLON RD

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/18/2003 FRAMING Approved IVRS - Inspection 0000*
09/17/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) 2-2 X 12 AT INTERIOR BEARING 2) BLOCK AND NAIL PORCH LEDGER TO BLOCKING PER DETAIL 3) STRAP CORNERS NOT CABIN TIED 4) NAIL PLATE CONDUCTORS IN GARAGE AND THROUGHOUT 5) REPAIR CUT CONDUCTOR ABOVE SLIDER 6) PLACE WATER LINES INSIDE WALL AT LAUNDRY 7) OVER BORED STUDS AT CONDENSATE 8) SEAL MOISTURE BARRIER AND CAULK EXTERIOR FOR STUCCO MESH 9) ANCHOR INTERIOR BEARING PER DETAIL 10) NOTE: REVIEW INTERIOR HOLDOWNS
09/16/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) SEE PREVIOUS INSPECTION 2) FOLLOW ALL DETAILS, TOO MANY ITEMS TO LIST 3) NOT A COMPLETE INSPECTION
09/15/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) TOO MANY ITEMS TO LIST, NOT A COMPLETE INSPECTION, SEE PREVIOUS REPORT
09/11/2003 FRAMING Denied IVRS - Inspection 0950*/ 1) A5 REQUIRES 4 X 4 POSTS AT GARAGE. GARAGE NOT PER 3/A8B 2) 12/A8A NOT COMPLIED WITH AT ALL WALLS INTERSECTION SHEARWALLS 3) NO TRUSS DRAWINGS ON SITE. CHECK 3 PT TRUSS BEARING 4) NO DWV WATER TEST 5) 1/A8A NOT COMPLIED WITH