Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/18/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 09/17/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) 2-2 X 12 AT INTERIOR BEARING 2) BLOCK AND NAIL PORCH LEDGER TO BLOCKING PER DETAIL 3) STRAP CORNERS NOT CABIN TIED 4) NAIL PLATE CONDUCTORS IN GARAGE AND THROUGHOUT 5) REPAIR CUT CONDUCTOR ABOVE SLIDER 6) PLACE WATER LINES INSIDE WALL AT LAUNDRY 7) OVER BORED STUDS AT CONDENSATE 8) SEAL MOISTURE BARRIER AND CAULK EXTERIOR FOR STUCCO MESH 9) ANCHOR INTERIOR BEARING PER DETAIL 10) NOTE: REVIEW INTERIOR HOLDOWNS |
| 09/16/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) SEE PREVIOUS INSPECTION 2) FOLLOW ALL DETAILS, TOO MANY ITEMS TO LIST 3) NOT A COMPLETE INSPECTION |
| 09/15/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) TOO MANY ITEMS TO LIST, NOT A COMPLETE INSPECTION, SEE PREVIOUS REPORT |
| 09/11/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0950*/ 1) A5 REQUIRES 4 X 4 POSTS AT GARAGE. GARAGE NOT PER 3/A8B 2) 12/A8A NOT COMPLIED WITH AT ALL WALLS INTERSECTION SHEARWALLS 3) NO TRUSS DRAWINGS ON SITE. CHECK 3 PT TRUSS BEARING 4) NO DWV WATER TEST 5) 1/A8A NOT COMPLIED WITH |