Date Description Inspector Results Comments
08/26/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
08/22/2003 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) SOUTH SIDE OF BAY WINDOW REAR, RUN SHEAR UP TO TOP CHORD 2) NAIL HORIZONTAL JOINT AT REAR 2ND FLOOR 3) FILL ALL NAIL HOLES IN GARAGE BEAM TO POST 4) NAIL ALL SHEAR TRANSFER PANELS TO ROOF. WILL LOOK FOR 8D'S AT INTERMEDIATES INSPECTION